Hospital High Frequency 40kHz Mammography X-ray Machine Cost

Model NO.: YSX980A/B
Input Power: Single Phase 220VAC, 50/60Hz
Weight: 200kg
Generator Type: High Frequency Inverter
Radiographic Ratings: Large Focal Point 20-35kv/1-
Frequency: 40kHz
Power Rating: 1.2kw
Sid: 65cm
Mammography X-ray Equipment No.: Ysx980A/B
Trademark: YSENMED
Transport Package: Standard Export Wooden Case
Specification: 3.5kw/5.0kw
Origin: China
Model NO.: YSX980A/B
Input Power: Single Phase 220VAC, 50/60Hz
Weight: 200kg
Generator Type: High Frequency Inverter
Radiographic Ratings: Large Focal Point 20-35kv/1-
Frequency: 40kHz
Power Rating: 1.2kw
Sid: 65cm
Mammography X-ray Equipment No.: Ysx980A/B
Trademark: YSENMED
Transport Package: Standard Export Wooden Case
Specification: 3.5kw/5.0kw
Origin: China
Hospital High Frequency 40kHz Mammography X-ray Machine Cost
 Model:   YSX980A/B

Hospital High Frequency 40kHz Mammography X-ray Machine Cost


X-ray Generator 
Generator Type High Frequency Inverter 40kHz
Input Power Single phase 220VAC, 50/60Hz
Radiographic Ratings Large Focal Point 20-35KV/1-300mAs
Small Focal Point 20-35KV/1-100mAs
Power Rating 1.2kW
Type High Frequency
 
 


Technical parameters and configuration:

X-ray Tube 
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
 

Radiographic Stand 
C-ARM: Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:±180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image Receptor 
18×24cm 
Line Voltage 
220Vac@15A,Single phase
Weight:200kg
Bucky: (Optional)
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:3.5:1 ,30 Line/cm
Comfortable Compression(Optional)
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure
(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional) 
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable 
for and film, screen, or method of radiography. 
Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps
 

Hospital High Frequency 40kHz Mammography X-ray Machine Cost
Hospital High Frequency 40kHz Mammography X-ray Machine Cost
Hospital High Frequency 40kHz Mammography X-ray Machine Cost

Hospital High Frequency 40kHz Mammography X-ray Machine Cost




  Hospital High Frequency 40kHz Mammography X-ray Machine Cost
 Model:   YSX980A/B

Hospital High Frequency 40kHz Mammography X-ray Machine Cost


X-ray Generator 
Generator Type High Frequency Inverter 40kHz
Input Power Single phase 220VAC, 50/60Hz
Radiographic Ratings Large Focal Point 20-35KV/1-300mAs
Small Focal Point 20-35KV/1-100mAs
Power Rating 1.2kW
Type High Frequency
 
 


Technical parameters and configuration:

X-ray Tube 
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
 

Radiographic Stand 
C-ARM: Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:±180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image Receptor 
18×24cm 
Line Voltage 
220Vac@15A,Single phase
Weight:200kg
Bucky: (Optional)
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:3.5:1 ,30 Line/cm
Comfortable Compression(Optional)
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure
(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional) 
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable 
for and film, screen, or method of radiography. 
Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps
 

Hospital High Frequency 40kHz Mammography X-ray Machine Cost
Hospital High Frequency 40kHz Mammography X-ray Machine Cost
Hospital High Frequency 40kHz Mammography X-ray Machine Cost

Hospital High Frequency 40kHz Mammography X-ray Machine Cost




 

Dental Impression Tray, is complete, suitable for the needs of patients in different regions, such as  European, American, fluorinated, with nets.

Dental impression tray,  have two material, PP material and ABS material. PP material is for single use. ABS material could be resuable and sterilized by autoclave.


Dental Impression Tray

Dental Impression Tray,Dental Impression Material,Dental Whitening Tray,Disposable Dental Impression Tray

Hebei Orient Imp. & Exp. Co. Ltd. , http://www.orientmedcare.com