Basic knowledge of medical device adverse event monitoring (13)

Release date: 2010-06-10


???????? ???????? 65. What are the more representative medical device adverse events in China? ???????? In China, the most influential, representative and representative medical device adverse events are Orthokeratology (OK) adverse events and polyacrylamide hydrogels that emerged after 1998. Adverse events. ???????? ???????? 66. What are the commonly used medical devices in the family? ???????? The commonly used medical devices in the family are sphygmomanometers, thermometers, blood glucose meters, contact lenses, insulin injection pens, etc. ???????? ???????? 67. What suspicious adverse events may occur during the use of the sphygmomanometer? ???????? Sphygmomanometer is an instrument for measuring blood pressure, mainly divided into two categories: mercury column sphygmomanometer and electronic (liquidless) sphygmomanometer. In the course of use, the sphygmomanometer may cause suspicious adverse events that may cause or may cause human injury. The main manifestations are inaccurate measurement results, intermittent black screen, and no display of blood pressure values. ???????? ???????? 68. What suspicious adverse events may occur in the thermometer during use? ???????? The thermometer is an instrument for measuring body temperature, the main forms are glass thermometer, electronic thermometer and infrared thermometer. The thermometer may cause suspicious adverse events that may cause or may cause human injury during use. The main manifestations are inaccurate measurement results, no rise/fall of mercury columns, and inability to count. ???????? ???????? 69. What suspicious adverse events may occur during the use of the meter? ???????? Blood glucose meter is an instrument used for self-glycemic monitoring of diabetic patients. It may cause suspicious adverse events that may cause or may cause human injury during use. The main manifestations are inaccurate blood glucose measurement values ​​and blood glucose levels. The display is not clear, the screen is not displayed, and so on. ???????? ???????? 70. What suspicious adverse events may occur in the use of insulin injection pens? Insulin pen is an ideal injection device for insulin therapy in diabetic patients. The front end is an injection needle, and the rear sleeve is filled with insulin. The size of the sleeve varies according to the type of insulin. Insulin pens may cause suspicious adverse events that may cause or may cause harm to the human body during use. The main manifestations are pain at the injection site, leakage of the injection needle, difficulty in pushing, poor pen seal, and discoloration of the refill. ???????? ???????? (Source: China Medical News)

Voriconazole

Voriconazole Cost,Voriconazole Price,Voriconazole Api,Voriconazole Intermediate

Xinxiang Haibin Pharmaceutical Co.,Ltd , https://www.carbapenemspharmacy.com