With the rise of small pulverizers and superfine pulverizers in the past two years, family health has gradually become popular. With the improvement of people's living standards, more and more people have realized that it is necessary to carry out the necessary and simple dietary processing in daily life, such as the crushing of some beans and nut foods, so some small crushers, The household pulverizer and the Chinese medicine pulverizer also sneaked into the kitchen of the ordinary family. In the long-term use of small crushers, there must be some problems, so we understand that some basic treatments are necessary.

First, the small pulverizer machine does not work or trip after power-on, there are possible reasons and treatment

1. The power supply is unreachable and the voltage is too low. Treatment: Check the power supply (knife gate, plug, fuse, motor wiring) to deal with the problem and ensure 380V voltage.

2. The small pulverizer magnetic starter fails; treatment: replace the magnetic actuator.

3. The motor burns out; the treatment method: replace the motor.

4. The power line of the small crusher is connected incorrectly; the treatment method: correct wiring.

Second, when the small crusher rebounds, does not cut the material, there are possible reasons and treatment

1. The motor is working in the wrong direction; the treatment method: communicate the three-wire wiring orientation of the three-phase line of the motor.

2. Feeding particle size exceeds the rule granularity; treatment method: feeding according to machine rule granularity.

3. The material moisture is too high; treatment: the material is monotonous and then broken.

4. Sieve hole gambling; treatment: clean up the sieve hole.

Third, the initiation of the protector can not be initiated normally, there are possible reasons and treatment

1. First feeding, after starting, crushing chamber gambling; treatment: first initiate, then feed.

2. There is too much material to be fed in one time. The treatment method is: evenly feeding.

3. The power supply is out of phase; check if the three-phase power supply is normal.

4. Thermal overload relay is out of regulation; Processing method: Scheduling the thermal overload relay current in the protector.

Fourth, there are abnormal dynamics in the operation of small pulverizers, and there are possible reasons and treatment methods.

1. Metal objects fall into the crushing chamber; Treatment: Check the materials to prevent metal contamination.

2. The hammer head and the small shaft are in contact with the sieve plate after being worn; the treatment method is: replacing the small shaft.

3. The machine fasteners are slack; the treatment method: fasten the fasteners.

Five, small crusher boring machine (card dead), there are possible reasons and treatment

1. Feed first, then turn on; treatment: stop and clean up. Start up and then feed.

2. Too much feed at one time; treatment: proper and uniform feeding.